Broadband Continuous Light Sources

Specifications
Feedback
Product Description
  • SMA905 output interface
  • Operating wavelength range 185-2500 nm
  • Five light source options available
LBTEK offers five types of broadband continuous light sources, including halogen lamps, xenon lamps, deuterium lamps, deuterium-tungsten lamps, and deuterium-halogen combined light sources, with an output wavelength range covering 185-2500 nm. All light sources feature a standard SMA905 fiber optic connector, which can be connected to fiber optic spectrometers for applications such as spectral analysis and colorimetric analysis. LBTEK provides compatible fiber optics and probes, as well as fiber optic attenuators with continuously adjustable attenuation ratios from 0-100%, to accommodate various application scenarios.
Halogen Lamps
  • Operating wavelength: 360-2000 nm
  • Lifetime: 2000 H
  • SMA905 standard interface output
  • Output fiber needs to be selected separately

LBTEK's Halogen Lamp is a versatile light source with high coupling efficiency, strong stability, high color temperature, and long service life, operating in the wavelength range of 360 nm to 2000 nm. Its output interface is SMA905, which enables maximum energy coupling with optical fibers. Due to the broad wavelength range of halogen light sources, it is recommended to pair them with IR600-1 near-infrared quartz fibers for optimal spectral performance. Halogen lamps are products designed for wide-spectrum measurements and irradiance calibration, suitable for various spectral applications. LBTEK offers customization services for halogen light sources with different power specifications. For specific customization needs, please contact LBTEK Technical Support.

Halogen light spectrum curve
Product Model
Operating Wavelength
Interface Type
Unit Price
Compare
Lead Time
LBHL2000-20W 360-2000 nmSMA905$934.283 weeks
LBHL1000 360-2500 nmSMA905$901.723 weeks
Deuterium Lamps
  • Operating wavelength: 185-600 nm
  • SMA905 standard interface output
  • Can be used as a light source for high-precision analytical instruments
  • Output fiber needs to be selected separately

LBTEK's Deuterium Lamps emit a continuous spectrum ranging from the ultraviolet band of 160-400 nm to the visible light range of 400-800 nm. Therefore, deuterium lamps can serve as high-precision light sources for analytical measurement instruments, such as liquid chromatographs and spectrometers. When using a deuterium lamp light source, it is recommended to pair it with the XSR600-1 UV-resistant quartz fiber. Since quartz also absorbs below 300 nm, when wavelengths below 300 nm are required, UV radiation-preprocessed optical fibers are necessary to achieve optimal performance.

Deuterium lamp spectral curve
Product Model
Operating Wavelength
Interface Type
Unit Price
Compare
Lead Time
LBD2000(25) 185-600 nmSMA905$884.073 weeks
Xenon Ultraviolet Lamps
  • Operating wavelength: 220-2000 nm
  • Modular heat dissipation method extends lamp life
  • SMA905 standard interface output
  • Output fiber needs to be selected separately

LBTEK provides a Xenon Ultraviolet Light Source with an output wavelength range of 200-2200 nm, which is a high-power full-spectrum light source with continuous wavelength distribution. It adopts imported xenon lamp bulbs and an advanced modular heat dissipation design to ensure concentrated and stable light energy output. The high-efficiency coupling SMA905 interface facilitates effective utilization of light in experiments. When using the xenon ultraviolet light source, it can be paired with the XSR600-1 UV-resistant quartz fiber. Since quartz also absorbs below 300 nm, when wavelengths below 300 nm are required, UV radiation-preprocessed optical fibers are necessary to achieve optimal performance.

Xenon Ultraviolet Lamp Spectral Curve Diagram

Product Model
Operating Wavelength
Connector Type
Unit Price
Compare
Lead Time
LBHPX2000 220-2000 nmSMA905$1741.473 weeks
Deuterium-Halogen Combined Light Sources
  • Operating wavelength: 190-400 nm & 360-2500 nm
  • Halogen lamp output intensity is adjustable, enabling balanced deuterium-halogen spectral output
  • SMA905 standard interface output
  • Output fiber needs to be selected separately

The illumination principle of tungsten halogen lamps is based on the principle of thermal radiation and the phenomenon of objects emitting light when heated. When sufficient current is applied to the filament, it heats up to an incandescent state and emits light. Its lifespan is related to the operating temperature—the higher the color temperature, the shorter the lifespan. The wavelength range of the deuterium-halogen combined light source provided by LBTEK typically spans from 360 nm to 2000 nm. When using the deuterium-halogen combined light source, it is recommended to pair it with the XSR600-1 UV-resistant quartz fiber, especially when utilizing wavelengths below 300 nm. Since quartz also absorbs light below 300 nm, UV-resistant pre-treated fibers are necessary to achieve optimal performance.

Deuterium-Halogen Combined Light Source Spectral Curve Diagram
Product Model
Operating Wavelength
Connector Type
Unit Price
Compare
Lead Time
LBDH2000 190-400 nm&360-2500 nmSMA905$1614.653 weeks
Deuterium-Tungsten Lamps
  • Operating wavelength: 185-2500 nm
  • SMA905 output interface
  • Output fiber needs to be selected separately

LBTEK's Compact Deuterium-Tungsten Light Source utilizes a high-frequency driven electrodeless discharge lamp (EDL), featuring small size, low power consumption, and long service life. The deuterium-tungsten lamp assembly consists of a deuterium lamp, tungsten lamp, shutter, and optical path system. Its operating wavelength range is 185 nm-2500 nm, with the deuterium lamp covering 185-400 nm and the tungsten lamp covering 400-2500 nm. Both lamps can be used independently as light sources. The output interface type is SMA905. When connected to a 12 V/0.6 A DC power supply, the green LED indicator lights up, requiring a 25-minute warm-up period. To minimize the impact of frequent power switching on the lamp's lifespan, the shutter is typically used to control the light source after warm-up. Additionally, the deuterium-tungsten lamp features external triggering capability, allowing independent TTL signal control of the deuterium lamp, tungsten lamp, and shutter.

Deuterium-Tungsten Lamp Spectral Curve Diagram

Product Model
Operating Wavelength
Interface Type
Unit Price
Compare
Lead Time
LBDH-mini 185-2500 nmSMA905$3175.73 weeks
Compact Halogen Lamps
  • Operating wavelength: 360-2500 nm
  • SMA905 output interface
  • Compact size, long service life
  • Output fiber needs to be selected separately

LBTEK's Compact Halogen Lamps feature small size, long lifespan, adjustable light intensity, and a broad wavelength range. These compact halogen lamps operate within a wavelength range of 360 nm to 2500 nm, with a standard SMA905 output interface. The output intensity can be adjusted via a potentiometer that regulates the filament current, offering an adjustment range of 0-100%, making them easy to integrate into various measurement devices to meet the reflection and transmission spectrum measurement needs of different samples. Due to the lamp's broad wavelength range, it is recommended to pair it with LBTEK's Large-Core Diameter Optical Fibers for optimal spectral performance. Powered by a 5V supply, LBTEK's Compact Halogen Lamps are small and flexible, making them suitable for conventional, simple, and rapid experimental testing applications.

Spectrum Curve of Compact Halogen Lamp
Product Model
Operating Wavelength
Interface Type
Type
Unit Price
Compare
Lead Time
LBLS1 360-2500 nmSMA905Adjustable light intensity$834.913 weeks